Rapp-it is intended as a temporary pipe repair for onsite emergency situations. However, Rapp-it has been known to last many years, providing sound structural pipe repairs. Ultimately, this is up to the discretion of the user.
Yes, Rapp-it can be used to stem the flow of the pipe leak until an alternative procedure can be completed. Isolating the pipes is the most effective repair however we understand this cannot always be done. In that instance simply turn down the pressure as low as possible when applying Rapp-it.
Absolutely. Rapp-it Pipe Repair is ideal for use in wet applications. We suggest the pipe be cleaned and roughened first to ensure a successful repair.
Yes, both Rapp-it Pipe Repair Bandage and Rapp-it Steel Putty can be used underwater in either fresh or salt water. Curing time may vary according to the temperature of the water. Cold water will increase the cure time and hot water will reduce the cure time.
Our recommended Rapp-it repair thickness is a minimum of 10mm or approximately 12-15 wraps around the pipe. We also recommend the repair extends 50mm either side of the wound area.
As soon as the foil bandage packet is opened the bandage will start to cure. Rapp-it Bandage has a working life of 4-5 minutes and a full cure time of 30 minutes. Rapp-it Steel Putty has a working life of 4-7 minutes and a full cure time of 30 minutes
Yes. We supply the RAP304 (100mm x 9m) for larger diameter pipes and elbows. Multiple bandages may be required for very large pipes.
Yes, Rapp-it Pipe Repair Bandage can be used alone. We do recommend the combination of Rapp-it Steel Putty along with our Rapp-it Pipe Repair Bandage to ensure a more successful pipe repair.
Rapp-it Pipe Repair Bandages can be removed with a hacksaw or angle grinder. Hammer and cold chisel is also an effective method of removing the bandage. When using an angle grinder, always use a respirator during the removal. All ways check the fluid/gas in the pipe first as fluid or medium may be flammable and ensure appropriate PPE (Personal Protection Equipment) is worn at all times.
Rapp-it’s shelf life is approximately 2 years from date of purchase if stored below 25°C (77°F), and the foil pouch is not punctured.
Yes, however as Rapp-it is a temporary repair we recommend a job and location report be filed so the repair location is recorded for when a permanent repair is arranged at a later date.
Rapp-it can safely handle (most not all) fluids and mediums from Potable Water (Drinking Water) to Sulphuric / Hydrochloric Acid and all industrial slurry.
Alatas Singapore Pte Ltd (Pipe Repair & Inspection Services)
1 International Business Park, #03-01E The Synergy, Singapore 609917
+65 6861 2336 +65 6861 6261 singapore@alatas.com
© 2016 Alatas Singapore Pte Ltd